Alton Pumps
PUMP FAULT GUIDE

Sewage pump keeps tripping — what it means and what to do

A sewage pump that repeatedly trips is being electrically protected from damage. This guide explains why it happens, the risks of ignoring it, and when immediate engineer intervention is required.

✔ Written by experienced pump engineers
✔ 120+ years combined engineering experience
✔ UK-wide emergency pump response
PUMP FAULT EXPERTISE

Professional sewage pump fault diagnosis

Pump engineer inspecting sewage pump system Contact Us Today

Sewage pump tripping is rarely a coincidence. It is a built-in safety response designed to prevent catastrophic failure. Early diagnosis prevents flooding, downtime and unnecessary pump replacement.

Electrical & mechanical fault diagnosis

Trusted pump engineers delivering safe, compliant and long-term pump solutions.


Domestic, commercial & critical pump systems

Trusted pump engineers delivering safe, compliant and long-term pump solutions.


Emergency and planned response available

Trusted pump engineers delivering safe, compliant and long-term pump solutions.

HOW IT HAPPENS

Why sewage pumps trip

Most sewage pump trips are caused by mechanical resistance or electrical overload. Identifying the root cause early prevents flooding, motor burnout and unnecessary replacement.

Request diagnosis
01
⚙️

Blocked impeller

Wipes, solids and debris restrict rotation, increasing load on the motor.

02
🔥

Motor overheating

Extended run times or incorrect pump sizing cause thermal overload.

03
⬆️

Float switch failure

Sticking or failed float switches create unsafe operating conditions.

04
💧

Water ingress

Moisture inside the motor windings triggers electrical protection.

05
🛠️

Bearing seizure

Mechanical resistance increases current draw beyond safe limits.

06
📟

Control panel fault

Incorrect settings or failed components cause repeated trips.

07

Electrical supply issues

Voltage imbalance or phase loss overloads the pump motor.

08

End-of-life pump

Worn motors draw excess current and trip under normal load.

ENGINEER INSIGHT

Why early diagnosis matters

Prevents motor burnout and full pump replacement

Early intervention reduces risk, cost and long-term system damage.

Avoids sewage flooding and contamination

Early intervention reduces risk, cost and long-term system damage.

Reduces emergency call-out costs

Early intervention reduces risk, cost and long-term system damage.

Extends overall pump system lifespan

Early intervention reduces risk, cost and long-term system damage.

Pump control panel diagnostics

Frequently asked questions

Can a blocked sewage pump cause tripping?

Yes. Blockages increase mechanical load, causing the motor to overheat and electrical protection to activate.

Is a tripping sewage pump dangerous?

It can be. Electrical faults and sewage overflow present health, safety and environmental risks if ignored.

Should a tripping sewage pump be repaired or replaced?

This depends on the cause, age and condition of the pump. A qualified engineer can advise on the most cost-effective solution.

Related pump services

Sewage pump tripping?

Our engineers provide rapid diagnosis and emergency repair to prevent flooding and further system damage.